(a.) Administration of alcohol after three series of measurement. The doses of 2 ml cognac per kg body 
weight were given and blood sampling taken between the series. 
(b.) Administration of alcohol at dinner the evening preceding the measurements. Doses were given 
according to individual taste and blood samplings were taken during dinner and during the first hours 
of work the following day. 
Fifteen values of the standard deviation for each operator were obtained each day. The differences 
between these values were tested according to Bartlett’s test. See tables 4.11:1 and 2 in the Appendix. 
The precision shows a great variation in investigation (a) while it is more uniform in investigation (b). 
The lack of uniformity in the first case may depend upon the degree of training. See fig. 4.11:1 in the 
Appendix. Most of the lack of uniformity must be caused, however, by factors other than experience and 
alcohol intake. In investigation (a) the correlation coefficients between blood alcohol concentration and 
standard deviation for each day and each operator were computed. See table 4.11:3. In investigation 
(b) a pooled standard deviation for each day and each operator, one value while influenced by alcohol 
and the other without this influence. The differences between these values were tested with an F-test. 
See table 4.11:4. In figures 4.11:2 through 9 in the Appendix results of the tests are shown graphically. 
In conclusion, the standard deviation of one setting in x, y and z in the model was approximately 
2 — 3 am on the image scale. The standard deviation of one parallax correction in a Zeiss stereocompa 
rator 18 X 18 cm was approximately 3—4 um on the image scale. Two of the operators tested were less 
experienced than the others. 
The variation in the precision during a day is clear. In this investigation it appeared that alcohol in 
take had no systematic effect on the variation. 
4.12 The Effect of Smoking 
As in the previous investigations, the precision was determined as a standard deviation of one setting 
in a series of 25 replicated settings. There were two types of smoking with three operators taking part in 
the tests. 
(a.) Eight series with smoking between every second series. 
(b.) Eight series with smoking between series nr 6 and 7. 
The variation of the precision has been studied with Bartlett’s and F-tests. The variation of the mean 
has been studied with variance analysis and t-tests. 
The results of these tests show that there is a lack of uniformity in standard deviations and indicates 
no significant connection with smoking. 
Reference, 4.1:1. Torlegard, K.: Investigations of Setting Precision under Various Conditions in Photo- 
grammetry, Svensk Lantmateritidskrift. Congress Number 1964. 
4.2 Tests of Coordinatographs 
The geometrical quality of coordinatographs was tested with methods similar to those used for tests 
of comparators. See reference 4.2:1. With the coordinatograph a regular grid net of 25 points was plotted 
on a sheet of material free from shrinkage. This sheet was then rotated through a right angle and the 
coordinates of the plotted points were measured with the coordinatograph. The sheet was rotated 
through another right angle, measured again, then rotated again and measured. Using the points 
originally plotted as given data, an adjustment of the discrepancies in the following positions, according 
to the method of least squares, revealed the most important regular errors of the coordinatograph, i.e., 
affine deformations and lack of orthogonality. The formal standard error of unit weight is more or less 
a precision determination as no absolute data were given. Standard deviation of unit weight might be a 
better expression here. For the practical application of the coordinatograph to photogrammetric plotting 
this is less important because possible absolute scale errors are compensated by the scale of the model.
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.