8
APPENDIX
Tables of the pointing error, S p , and its estimated standard
deviation for high contrast circular targets.
A. Means based
on 5 series of 50
observations
(i) Measuring mark diameter
2.23 minutes of
Target Visual
Annulus
S
Angle (min.)
width (min.)
(Sec?)
2.53
0.15
1.40 ± .1
3.08
0.34
2.40 ± .2
3.40
0.59
3.50 ± .3
4.13
0.95
5.54 ± .3
4.90
1.34
5.42 ± .2
10.00
3.89
5.44 ^ .1
15.10
6.44
7.66 ± .2
20*10
8.94
8.36 ± .3
29.93
13.85
12.69 ± .4
(ii) Measuring mark diameter
3.42 minutes of
Target Visual
Annulus
S P
Angle (min.)
width (min.)
(Sec?)
3.75
0.17
1.17 .1
4.53
0.56
4.08 ±- .1
4.90
0.74
4.98 ±- .5
10.00
3.29
5.26 ±- .5
15.10
5.84
6.70 ± .2
17.50
7.04
8.18 ± .7
20.10
8.34
8.77 ± .6
29.93
13.25
13.26 ± .6
(iii) Measuring mark diameter
17.75 minutes o:
Target Visual
Annulus
s p
Angle (min.)
width (min.)
(Sec.)
18.10
0.18
1.43 ± .1
18.52
0.39
2.84 ± .1
20.10
1.18
4.88 ±- .3
22.84
2.55
4.25 ±- .3
29.93
6.09
5.86 ± .1
44.93
13.09
13.07 ±- .6