65
8.3.3. Interior Orientation
In this case the interior orientation is defined by three co-ordinates, which
give the location of focus in the system of the fiducial marks. The results are
shown in Table 13.
liable 13. Elements of interior orientation and their standard errors. Roent
genograms from an iodine 125 radiation source. Values in milli
meters.
Picture
number
x Q
v
** o
Vo
s
/0
c
s c
21
— 1.156
.239
2.831
.398
37.042
.241
22
— .322
.885
2.396
.801
37.260
Ml
23
— 1.670
.827
1.607
.482
36.830
.502
24
—1.748
1.048
2.249
1.040
36.208
.700
25
— 1.630
.858
3.249
.765
36.535
.569
26
—1.055
.681
1.393
.632
37.374
.422
27
— 1.273
.242
1.709
.424
37.320
.243
28
— 1.409
.305
1.592
.283
37.357
.200
29
— .726
.669
2.208
.607
37.538
.415
210
— .420
.559
2.334
.502
37.062
.335
211
— 1.820
.852
1.118
.794
37.368
.534
212
—1.486
.698
1.630
.646
37.392
.450
213
— .933
.188
1.789
.327
37.372
.188
214
— 1.269
.800
1.418
.747
38.092
.517
215
— .988
.774
1.920
.709
37.851
.483
216
— .958
.444
1.732
.405
37.425
.269
217
— .315
.690
1.773
.621
37.744
.396
218
—1.800
.533
1.076
.520
37.193
.360
Variance
between
0.244089
0.321348
0.197170
Variance
within
0.455594
0.389685
0.187055
F (17, 146)
0.563
0.824
1.053
Test
not significant
not significant
not significant
Mean
— 1.165
1.890
37.276
Standard
error of
the mean
.159
.147
.102