Full text: Actes du 7ième Congrès International de Photogrammétrie (Premier fascicule)

(17) 
Italian Cameras 
Camera 
Santoni III 
double camera 
Santoni IV 
AFL 92/A-Nistri 
FOMA 93/A- 
Nistri 
Weight (loaded). 
82 kg 
18 kg 
80 kg 
Outside dimen 
sions. 
51 x 48 x 55 cm 
high 
32 x 28 x 37 cm 
high 
38 x 54 x 49 cm 
high 
40 x 35 x 44 cm 
high 
Lenses 
Aerogon 
195 mm, f :5 - 0 
some fluorided 
Triogon 
135 mm or 
165 mm, f:6 • 3 
fluorided 
OMI Vega 
20 cm, f:6-3 
OMI Orthosix 
20 cm, f:6 • 3 
both fluorided 
OMI Aldebaron 
21 cm, f :4 • 5 
OMI Rigel 
12-5 cm, f :6 • 3 
both fluorided 
Resolution test. . 
Targets consist of two bright lines 
on dark background in collima 
tor of 1 metre focal length 
Foucault targets 
Shutter 
central with five sectors 1/50-1/250 
central 1/150 
central 1/100- 
1/350 
Operation 
Electrical or 
manual 
Electrical or 
manual 
Electrical 
Electrical or 
manual 
Minimum expo 
sure interval. 
5 sec. 
4 sec. 
4 sec. 
4 sec. 
Format 
13 x 18 cm 
18 x 20 cm 
13 x 18 cm 
18 x 18 cm 
Exposures 
120 plates per 
section 
300 on film 
144 plates 
260 on film 
Method of hold 
ing film. 
vacuum from bellows 
vacuum 
Filters 
Yellow Gi and 
Gn without 
graded density 
Yellow 
Yellow-orange 
Yellow-orange 
with graded 
density 
Items photo 
graphed. 
counter, focal 
length 
spherical level 
bubble, coun- 
bubble level, 
counter 
bubble level, 
counter 
ter, focal 
length 
Netherlands 
Cameras used are described previously or elsewhere in these Archives. 
Filters used with the Wild cameras are yellow 450 millimicrons (1-3X), yellow 
500 millimicrons (2X), and orange 600 millimicrons (4X). The minus blue (12) 
is used with the O.S.C., and the Zeiss light yellow, yellow, and orange filters 
with the RMK P-10. 
New Zealand 
The Eagle IV cameras fitted with Ross 8j" f :4 - 5 fluorided lenses weigh 30 
lbs. They have a louvre shutter behind the lens with a speed of 1/200 second. 
Operation is electric with a minimum interval between exposures of 3 seconds. 
175 exposures 9" x 7" are obtained on film. A K2 filter is used without graded 
density. A counter, data card, altimeter, and watch are photographed. 
Sweden 
Preliminary resolving power tests have been made for the RMK 20/3030 
from an altitude of 400 m using a low contrast annulus target 6 . The RMK 
20/3030 used in Sweden has a special suction back 7 , kilters used are mainly 
the Zeiss D, but also the B and C with some others for special investigations.
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.