PHOTOGRAMMETRIC ENGINEERING & REMOTE SENSING, 1975
REFERENCES
l. Abdel-Aziz, Y. I., and H. M. Karara, "Direct Linear Transformation from Comparator Coordinates
into Object Space Coordinates in Close-Range Photogrammetry", Proceedings of Symposium on
Close-Range Photogrammetry, Urbana, Ill. 1971.
. Abdel-Aziz, Y.I., and H. M. Karara, “Photogrammetric Potentials of Non-Metric Cameras”, Civil
Engineering Studies, Photogrammetry Series No. 36, University of Illinois, Urbana—Champaign,
Ill., 1974.
. Ackermann, F. et al. ^Aerotriangulation with Independent Models", Nachrichten aus dem Karten-
und Vermessungswesen, 1972.
. Bóttinger, W. U., “On Some Aspects of Taking Close-Range Photographs for Photogrammetric
Evaluation—Practical Experiences in Photographing the Models of the Cable-Net Roofs for the
Olympiad at Munich”, International Archives of Photogrammetry, Commission V, 1972.
. Brandow, V. D., et al. “Close Range Photogrammetry for Mapping Geologic Structures in Mines”,
Proceedings of Symposium on Close Range Photogrammetric Systems, Champaign, Ill., 1975.
. Brown, D. C., “Close Range Camera Calibration”, Photogrammetric Engineering, 1971.
. Dohler, M., “Nahbildmessung mit Nichtmesskammern", Bildmessung und Luftbildwesen, 1971.
. Faig, W., "Calibration of Close Range Photogrammetric Cameras", Proceedings of Symposium on
Close Range Photogrammetry, Urbana, Ill. 1971.
. Faig, W., "Precision Plotting of Non-Metric Photography", Proceedings of Biostereometrics '74
Symposium, Washington D.C. 1974.
. Faig, W., “Photogrammetric Equipment Systems with Non-Metric Cameras”, Proceedings of Sym-
posium on Close Range Photogrammetric Systems, Champaign, Ill., 1975.
. Faig, W., and H. Moniwa, “Convergent Photos for Close Range”, Photogrammetric Engineering,
1973.
. Harley, I. A., “The Calibration of Cameras for Non-Topographical Photogrammetry”, Journal of the
Japan Society of Photogrammetry, 1966.
. Jaksic, Z., “Analytical Instruments in Close Range Photogrammetry”, Proceedings of Symposium on
Close Range Photogrammetric Systems, Champaign, Ill. 1975.
. Karara, H. M., and W. Faig, “Interior Orientation in Close Range Photogrammetry: An Analysis of
Alternative Approaches, International Archives of Photogrammetry, Commission V, 1972.
. Kólbl, O., "Selbstkalibrierung von Aufnahmekammern", Bildmessung und Luftbildwesen, 1972.
. Kólbl, O., "Tangential and Asymmetric Lens Distortions, Determined by Self Calibration", Proceed-
ings of Symposium of Commission III, 1.S.P., Stuttgart, Germany, 1974.
. Linkwitz, K., "Some Remarks on Present Investigations on Calibration of Close Range Cameras",
International Archives of Photogrammetry, Commission V, 1972.
. Malhotra, R. C., and H. M. Karara, “A Computational Procedure and Software for Establishing a
Stable Three-Dimensional Test Area for Close Range Applications", Proceedings of Symposiums on
Close Range Photogrammetric Systems, Champaign, Ill. 1975.
. Marzan, G. T. and H. M. Karara, "A Computer Program for Direct Linear Transformation Solution of
the Collinearity Condition and some Applications of it" Proceedings of Symposium on Close Range
Photogrammetric Systems, Champaign, Ill. 1975.
. Merritt, E. L., "Procedure for Calibrating Telephoto Lenses", Proceedings of Symposium on Close-
Range Photogrammetric Systems, Champaign, Ill. 1975.
. Torlegárd, K., On the Determination of Interior Orientation of Close- Up Cameras Under Opera-
tional Conditions Using Three Dimensional Test Objects, Dissertation, Stockholm, Sweden, 1967.
. Wolf, P. R., and S. A. Loomer, “Calibration of Non-Metric Cameras", Proceedings of Symposium on
Close Range Photogrammetric Systems, Champaign, Ill. 1975.
. Woodhead, R., Systems and Systems Approach, Working Paper in Civil Engineering, University of
Illinois, 1970.