66 Wester-Ebbinghaus, W.
FRG
Calibration of the setting elements of a rectifier
Vérification des données de mise en place d’un rectificateur
Überprüfung der Einstellemente eines Entzerrungsgerätes
If the interior and exterior orien
tation of an image is known, it
is possible to find the tilt-data
for its rectification.
It will be demonstrated which
demands have to be met in order
to get a photomosaic of in
tended accuracy.
While the calibration of the dis
plays of the scale and the image-
displacement does not present
much difficulty, the checking of
the tilt elements, however, causes
more problems. With the excep
tion of the Rectimat (Jenoptik,
Jena) the picture carrier of all
rectifiers consists of two glass
plates causing distortion which
depends on the rectification-tilt.
To calibrate a SEG V (Carl Zeiss,
Oberkochen) a grid plate con
sisting 11x11 grid-points was
projected under different tilt
positions on ultraflat photo plat
es. A numerical transformation
with parameters for tangential
and radial distortion shows the
functional interrelation between
tilt and distortion.
It will be demonstrated to what
extent this distortion can be tak
en account of by means of tilt-
data.
Les données de mise en place
pour la rectification d’un photo
gramme se déduisent de l’orien
tation de celui-ci.
L’auteur indique ce qu’il faut
exiger des données de mise en
place, afin d’obtenir une mosaïque
redressée d’une précision don
née.
Alors que l’étalonnage des
graduations pour l’échelle et
par les déplacements de l’image
ne présente pas de grosses
difficultés, le contrôle de l’indi
cation de l’inclinaison pose cer
tains problèmes. Tous les recti-
ficateurs connus, à l’exception
du Rectimat de la firme Jenoptik,
Jena, sont pourvus d’un support
constitué par deux plaques de
verre, à l’intérieur duquel on
introduit l’original. Ceci cause
une distorsion variant avec l’in
clinaison.
Afin de vérifier un SEG V de la
firme Cari Zeiss, Oberkochen,
on a procédé à la projection
d’une plaque photographique
Ultraflat selon différentes incli
naisons. Une transformation
numérique avec des paramètres
pour les distorsions tangentielle
et radiale montre le lien fonction
nel entre la distorsion et l’in
clinaison.
L’auteur examine les possibi
lités de tenir compte de l’in
fluence de la distorsion lors
du réglage des valeurs de l’in
clinaison.
67 Zotov, G., Alexandrov, P.
USSR
Progress of photogrammetric equipment in the USSR
Perfectionnement des appareils photogrammétriques en URSS.
Vervollkommnung der photogrammetrischen Geräte in der UdSSR
Progress in photogrammetric
equipment is being developed
in the direction of instrumental
precision improvement, photo
gram error correction, enlarge
ment of plotted photos with in
creased range of tilt angles and
focal length, partial or total auto
mation of individual plotting and
processing processes.
Le perfectionnement des ap
pareils photogrammétriques est
éffectué en vue de l’amélioration
de leur précision instrumentale,
de l’évaluation et la correction
des erreurs systématiques d’une
photographie, de l’augmentation
du format restitué et de la
marge des valeurs d’installation
des paramètres d’orientation
Bei bekannter Orientierung eines
Messbildes lassen sich die Ein
stellwerte für seine Entzerrung
ableiten.
Es wird gezeigt, welche Anfor
derungen an die Einstellelemente
gestellt werden müssen, um
einen Bildplan gewünschter Ge
nauigkeit zu erhalten.
Während die Eichung der Skalen
für den Massstab und die Bild
verschiebungen keine grossen
Schwierigkeiten bereiten, ist die
Überprüfung der Neigungsan
zeige mit einigen Problemen
verbunden. Mit Ausnahme des
Rectimat von Jenoptik, Jena,
wird das Original bei allen be
kannten Entzerrungsgeräten in
eine aus zwei Glasplatten be
stehende Bildbühne eingelegt.
Dies bedingt eine von der Nei
gung abhängige Verzeichnung.
Zur Überprüfung eines SEG V
von Carl Zeiss, Oberkochen,
wurde eine Glasgitterplatte bei
verschiedenen Neigungen auf
Ultraflat-Photoplatten projiziert.
Eine numerische Transformation
mit Parametern für tangentiale
und radiale Verzeichnung zeigt
den funktionalen Zusammen
hang zwischen Verzeichnung
und Neigung.
Es wird untersucht, inwieweit
der Einfluss der Verzeichnung
bei der Einstellung der Neigungs
werte berücksichtigt werden
kann.
Wichtige Fortschritte für die
photogrammetrischen Geräte
wurden durch die Erhöhung der
Gerätegenauigkeit, Berücksichti
gung der systematischen Bild
fehler, Vergrösserung des Aus
wertebereiches für unterschied
lich grosse Bildorientierungs
elemente, teilweise und vollstän
dige Automatisierung einiger