n of table 1, that
r
5. CONCLUSIONS References from Other Literature:
This study shows that the error of the tracking device cannotbe [6] Azuma, R.; Baillot, Y.; Behringer, R.; Feiner, S.; Julier,
ignored. The results differ significantly between calibration S.; MacIntyre, B.: "Recent Advances in Augmented
with and without assuming an error model for the tracker Reality", IEEE Computer Graphics and Applications 21, 6
measurements. Especially a second tracking device improves (Nov/Dec 2001), 34-47.
the reproducibility of the calibration results for a see-through
f observations is
bird is left away,
free. Then, using
ed consequently.
icant differences
thod proposed in
with column four
rease of accuracy
(B). This is the
nage points are
ce of the tracker
' table 2. When
or free and only
ts are still better
points necessary
y ten points, the
Otherwise, there
tion when using
> accuracy of the
f the parameters
to the display-
qe]
tandard
ation (B)
8.2841
7.1293
0
0
0.0053
0.0107
0.0482
0.0679
0.0221
0.0632
cker is assumed
30
32.4118
6.8377
0
0
0.0068
0.0035
0.0085
0.0764
0.0077
0.0813
bserved image
ed parameter.
augmented reality system.
6. REFERENCES
References from websites:
[1]
[2]
Ascension Technology Cooperation: "Flock of Birds",
http://www .ascension-tech.com/products/flockofbirds,
(cited 02.02.02).
Colaborative Research Center 461, http://www-
sfb461.physik.uni-karlsruhe.de/, (cited 02.02.02).
References from Books:
[3]
[4]
[5]
Buchholtz, A.; Rüger, W.: "Photogrammetrie: Verfahren
und Geräte", VEB Verlag für Bauwesen Berlin, dritte
Auflage, 1973, Berlin.
Gamma, E.; Helm, R.; Johnson, R.; Vlissides, J.: Design
Patterns, Addison Wesley Publishing Company, ISBN 0-
201-63361-2, Bonn, 1995.
Wolf, H., Ausgleichungsrechnung I, Formeln zur
praktischen Anwendung, 2. Auflage, Dümmlerverlag,
Bonn, 1994.
[7]
[8]
[9]
[11]
—539—
Ghazisadedy, M.; Adamczyk, D.; Sandlin, D. J.; Kenyon,
R. V.; DeFanti, T. A.: "Ultrasonic Calibration of a
Magnetic Tracker in a Virtual Reality Space", Proc. of
IEEE Virtual Reality Annual International Symposium
pp. 179-188, 1995.
Janin, A. L.; Mizell, D.; Caudell, T.: "Calibration of head-
mounted displays for augmented reality applications", in
Proc. of VRAIS '93 (Seattle, WA, Sept. 1993), pp. 246--
SS.
Kindratenko, V.: "A survey of electromagnetic position
tracker calibration techniques", Virtual Reality: Research,
Development, and Applications, 2000, vol. 5, no. 3, pp.
169-182.
Raab, F.; Blood, E.; Steiner, T.; Jones, H.: "Magnetic
position and orientation tracking system", IEEE
Transactions on Aerospace and Electronic Systems, Vol.
15, No. 5, 1979, pp. 709-718.
Tuceryan, M.; Navab, N.: "Single point active alignment
method (SPAAM) for optical see-through HMD
calibration for AR Augmented Reality", 2000. (ISAR
2000). Proceedings. IEEE and ACM International
Symposium on , 2000 Page(s): 149 -158