59
T T T 2 n
I T
10 20 30 40 50
Diagram 13. Ordinary aerial triangulation. Standard errors of the three angles of the
exterior orientation. Cantilever extension. s, — l.
so = 0,01 mm the standard errors are graphically demonstrated in
diagrams 13— 14.
In a similar way the accuracy of the elements of the external orienta-
tion can be determined for other geometrical conditions. We will later
on demonstrate how convergent aerial photography can be treated.
€
3.2. The error accumulation formulae for model coordinates
In order to find the error accumulation formulae for the model coordi-
nates from the corresponding formulae of the elements of the external
orientation we have to use the differential relations between the elements
of the external orientation and the model coordinates.
The general formulae are wellknown and can be written as follows
for a model r — 1,7
(x — b)y xy (x? + h?) (x — b) _
De ir 5 Du, À ) Dx, m Dy, +
p f(y — by h?} x — b)y
l J : 1
o. io Des
m De, m (Do, _, Do,) +
x (x — b) x — b Dx x Bx 990
bh (Dbz,_, — Dbz,) — p PA 9^ (229)