Full text: Proceedings, XXth congress (Part 1)

   
International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, Vol XXXV, Part Bl. Istanbul 2004 
  
RMS Errors on the Control Points [m 
Scene No. 
X 
01 +1.8 
02 z 1.9 
03 +1.9 
04 +24 
All Scenes + 1.6 
tA | oc 
Y 
+2 
+ à. 
= 2. 
= 
zd 
ol 
  
RMS Errors on the Check Points [m 
Y 
20 
3.2 
ais 
+22 
Z 
im [1 
to 
bi E Mel 
2.1 
Table 3. RMSE of the orientation results of block scenes HRS SPOT 5 
4. THE METHODOLOGY OF DTM GENERATION ON 
THE BASIS OF PANCHROMATIC HRV SPOT 4 DATA 
4.1 Specification of methodology 
The methodology of measurement of DTM on the 
panchromatic images HRV SPOT 4 was elaborated. The 
modules of photogrammetric software’s like MATCH - T 
Inpho and Image Station Automatic Elevation Collection 
(ISAE) Z/I Imaging were used for measurements of grid 
of elevation points with rows and columns spaced 
dependent from terrain type. 
The basic factors influencing the results of correlation 
measurement of DTM are described in Ph.D. thesis of 
Mr. Ewiak. The most important factors are: 
- . Radiometric accuracy of SPOT 4 images; 
- Accuracy of delimitation of Rational Function 
Coefficients for stereoscopic SPOT 4 Pan scene; 
- Method of correlation; 
- Parameters of the software used for auto- 
correlation measurement of height-points. 
Close correlation was found between accuracy of DTM and the 
radiometric accuracy of SPOT 4 images. In order to assure 
maximum effectiveness of correlation measurement, the 
optimum radiometric processing has been done on the raw 
panchromatic SPOT 4 scenes. 
It has been also found that the accuracy of delimitation of 
Rational Function Coefficients, responsible for the correctness 
of exterior orientation parameters of SPOT 4 scenes, influences 
fundamentally the accuracy of measurement of DTM. 
It show also, that the incompetent usage the added parameters 
of software realizing the correlation measurement of the DTM 
can demote the accuracy of height measurements. 
The problem of limitations of MATCH - T as well as the ISAE 
was solved. This problem concerned the admissible size of 
measuring grid of DTM for stereoscopic SPOT 4 images. 
4.2 The results of measurement of DTM 
The measurements of DTM were performed on the 
separated fragments (“Region I” and "Region II") of 
stereoscopic scene SPOT 4. The rational function 
coefficients were calculated in independent process. 
For the "Region I" the grid of height-points was generated with 
spacing 25m and for "Region Il " with spacing of 100m. The 
accuracy of measured DTM were examined on the basis of their 
comparison with reference DTM, which were obtained by auto- 
correlation methods from aerial photographs in scale 1:26 000, 
with manual edition. 
The accuracy of reference DTM was estimated as RMS Z = + 
0.5m. The results of analyses of accuracy for each DTM, taking 
into account the influence of the factors described above is 
shown in table 4. 
The use of elaborated methodology, permitted to measure 
DTM with accuracy RMS Z = + 4,7 m for mountainous and 
hilly terrain and RMS Z = + 2.6 m for flat terrain. 
Additionally, Mr. Ewiak has elaborated software for filtration of 
wrong DTM points and their removal, as well as the 
interpolation of new points on the basis of the analysis of 
neighboring terrain. The software is written in programming 
language Borland Delphi 6.0 for the operating systems 
Windows NT, 2000, XP. Using this software the accuracy of 
DTM was increased to RMS Z = £3.9 m for mountainous 
and hilly terrain and to RMS Z = + 1.8 m for flat terrain. 
  
The factors influencing accuracy of correlation measurement of DTM 
RMS on height points of DTM 
for different test regions [m] 
  
  
  
Region I Region II 
Raw images of SPOT 4 + 8.8 *4s 
Radiometric accuracy of images + 8.4 t4.] 
Accuracy of delimitation of Rational Function Coefficient r786 + 3.4 
Selection of software parameters t 6.8 t 2.6 
The grid size of DTM + 4.7 +26 
  
  
  
  
Table 4. The influence of basic factors on results of measurement of DTM by correlation method of the HRV SPOT 4 
   
   
    
     
   
   
   
   
   
   
    
   
      
   
  
     
    
    
    
   
   
   
    
    
   
  
  
  
  
  
  
  
  
  
  
  
[nter 
— 
Epip 
imag 
matc 
have 
16-b 
only 
inter 
Gen 
gros 
in ta 
For 
rang 
imag 
The 
mea 
perr 
acci 
pan 
date 
Tec 
ins 
be ı 
Afr 
can 
and 
To 
basi 
suit 
add 
etc. 
   
 
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.