Figure 2: X-Band Data with Fitted Response and Nominal Envelope
5.4, Comments on the above Experiments
The experiments described in the previous section did not
achieve, or fully achieve, their calibration objectives.
Valuable information was collected during these activities,
contributing, if carefully analysed, to the characterisation of
parts, or subsystems, of the end-to-end chain.
The analysis of the corner reflectors in [2] and [17]
characterises the processor performance,
It is important to decide whether the above results
constitute a "calibration" in the sense of Section 1. In
general, the answer is "no" — at best, they allow comparison of
some scenes where reference signals and/or targets are
available.
In both cases, to a different degree, the calibration has
been an "a posteriori" exercise. In the CV580 experiment, where
more precautions were taken, there was no stated objective in
terms of the accuracy and precision of the derived og value.