; A special mention should be
made of some agencies for their prominent participation which
permitted to draw efficient and numerous comparisons of pro-
ducts; among them I would like to quote, (See LIST OF OPERATIVE CENTERS.) :
. GID (DR), IGM (1), IGN (F), IPUS (D), ITPT (I).for prepa-
ration of control, check points and contours.
. IFAG (D), IGN (F), ITC (NL), for production of the major
part of the required ortho and stereo-orthophotos, as well
as NBS (SF), NLS (S) and the Wild Company (WH) for the
useful complementary products they delivered.
: . IGN (F), IPTU (A) for carrying out the major part of the
measurements; NRC(CDN) and UCL (GB), for the additional
part they were able to take regarding measurements.
. IGN (F) and its school (E.N.S.G) that fostered completion
of the test, so that full results could be obtained from
these measurements and conclusions fully drawn.
Five centers produced ortho and stereo-orthophotographs using a
to WILD-OR 1 (IGN (F), ITC (NL), NB S (SF), NLS (S) and WH (CH) and
a sixth center used a Zeiss- Z 2 (IFAG (D).
MEASUREMENTS Six instruments were used for measurements onto the products deli-
S vered to the four assessing centers, as follows
i) IGN (F) used the ORTOSTER, a home made prototype, fitted
with encoders,storing data on tapes. This ORTOSTER accepts
a large format of size 330 x 570 mm, and has resolutions of
2 cmm in x, y and 1 cmm in px, free hand motion, and fine-
adjustement track-ball devices.
ii) IPTU (A) used a STEREOGRAPH, from R and A.ROST C" (Wien,(A))
fitted with Diadur glass scale of 1 cmm resolution,storing
data on tapes. The STEREOGRAPH accepts a very large format of
size up to 550 x 750 mm, has a free hand motion and fine
adjustment screws.
iii) NRC (CDN) used its STEREOCOMPILER, built in its laboratories,
which was specifically designed to accomodate stereo-orthopho-
tos and had been in use for about twelve years for research
purposes.
This instrument accepts a very large format of size up to
400 x 720 mm, has resolutions of 1 cmm but did not store data
on tape,while delivering x, y and px listings; it has a free
hand motion device with air bearings and a px micrometer.
iiii) UCL (GB) used three types of instruments
. a CP1 stereoplotter modified to plot from stereo-orthophotos,
which accepts small formats of size 250 x 250 mm; it has
n^ a free hand motion device and a px measurement by footwheel.
. a KERN DSR1 analytical stereoplotter accepting a small format
of 250 x 250 mm and storing very accurate data on a floppy
disc.
. a ROSS stereo-orthophoto plotter developped by ROSS Instruments
Ltd., and commissioned by the OS (GB). The prototype was made
available to UCL (GB). It accepts a large format of size 400 x
400 mm and has a free hand motion devicé, a tracker ball and
a joystick for px removal, ( ALI, J and I.J. DOWMAN ).
Eight combinations of stereo-orthophoto printers and compilers
were thus obtained.
Each product or arrangement of products has been measured by
two rounds, sometimes three rounds, each of them including
E closure measurements on GCPs.
601