An investigation of the warm-up of the lamp and the
sensor has shown a strong influence during the first 3
minutes. The gray values of an area of the gray scale has
changed from the switch on to 3 minutes later from 147 to
179. After 3 minutes stable conditions have been reached
with no stronger change than 2 to 3 gray values. The
remaining changes may be caused by a change of the
voltage.
7. Conclusion
The CCD-lines and arrays do have a limited dynamic
range in relation to aerial images, by this reason it is
necessary to use the optimal settings for the scanner. The
time consuming empirical determination can be replaced
by a pre-scan with a desktop scanner. Based on the pre-
scan with a developed table the settings can be found
within one minute. Nevertheless a loss of information will
happen in the dark parts. By this reason problems are
existing in scanning photo negatives. With photo positives
and color images which shall be scanned only black and
white, no real radiometric problems are existing.
The geometric accuracy of the RM1 corresponds to an
analytical plotter, that means, it is sufficient also for jobs
where precision is required like image correlation and
block triangulation.
The pixel size of 12um is corresponding to the usual
resolution of aerial photos. A smaller pixel size will not
improve the quality of the digital image. Because of the
large file size of the digitized images (~360 Mb for one
channel, 1.06 Gb for the 3 color channels together) very
often the pixel size is reduced to 24pm.
References
Jacobsen, K.1980: Attempt at Obtaining the Best
Possible Accuracy in Bundle Block Adjustment,
ISP Hamburg 1980 und Photogrametria 1982,
p 219 - 235
Jacobsen, K. 1982: Selection of Additional Parameters by
Program, ISPRS Com lll, Helsinki
Jacobsen, K 1984: Analysis of Remaining Systematic
Image Errors, ISPRS Rio de Janeiro
Bósemann, W., Jacobsen, K. 1995: Kalibrierung digitaler
Bildaufnahmesysteme, DGPF Jahrestagung
Hannover
Wehrmann, H. 1995, Kalibrierung des Photoscanners
RM1 Rastermaster, Diploma Thesis, University
of Hannover
77
RM 1
Ne
WEMIILI & ABBOCIATES
Figure 12: Rastermaster RM1
International Archives of Photogrammetry and Remote Sensing. Vol. XXXI, Part B1. Vienna 1996