Between the mean values for y-parallaxes in 3*2 and 3*3
a difference pf 1*7^* appeared* If one takes a level of
probability of 95% this difference is significant* If
however, the level of probability is fixed to 99%* there
is no more significant difference*
Strip tr.i angulation with the Analytical Plotter AP/C-3
One strip with 5 models of the test area Heitlingen
has been measured* Photo scale was is 7000 . In every
model 12 natural points have been measured for relative
orientation and point transfer. After relative orientation
being complete, 12 signalized control points have been
measured for strip adjustment, by polynomials. The table
gives the time needed for this operations:
model 54/52
73
min
' model 52/50
54
min
■ 4
t '
model 50/48
42
min
model 48/46
49
min
-
‘w , /■
model 46/44
52
min
■ ? ■
. ; ;
f 4 1
total
4 h 30
min
r
The results of the strip adjustment were unfortunately
very disappointing. The residuls remaining in the
control points were 3& cm in x and l7 cm in y* The only
explanation that can be given for the moment is that there
might be still some improprieties in program execution.