The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences. Vol. XXXVII. Part B5. Beijing 2008
The six most deteriorated images among the rotated ones were
then excluded (images no. 11, 12, 13, 14, 16 and 18). These
reduced twelve images versions (versions 11, 12, 13, 14 and 15
in Table 2) give better sigmaO and precision values. However, a
systematic pattern of the image coordinate residuals still
remains, varying from image to image. Note that version 15
stands for the free network adjustment. After Brown’s 10
additional parameter set, Gruen’s (1978) 44 additional
parameter set was applied. The block-invariant 44 additional
parameters did not compensate the systematic errors as well
(version 12).
3.2 Accuracy test of N93
The accuracy test of N93, also based on block-invariant APs,
apparently gives better results. The sigmaO is a quarter of a
pixel. A systematic error pattern still remains in the residuals
(Figure 7c and 7d), however, the magnitude is much less than in
the K750i’s case. It has clearly achieved sub-millimeter
accuracy in object space (versions 22 and 23 in Table 3) in all
coordinate directions.
3.3 Accuracy test of W100
The W100 gives slightly better theoretical precision and
empirical accuracy values than the N93 (Table 4). The standard
deviation of image observations is in the same range with the
N93, i.e. one quarter of a pixel. The W100 reveals similar
residual errors like the N93 regarding the magnitude (Figure 7e
and 7f).
3.4 Accuracy test of F828
The F828 gives the best performance and remarkably superior
numbers compared to the other cameras (Table 5). SigmaO goes
down to 1/10 of a pixel, satisfying the theoretical expectations
of the Least Squares template matching. Also, the empirical
RMSEs are here in much better agreement with the theoretical
standard deviations.
Ver
GCP
CHK
TIE
APs
Rej
SigmaO
STD-X
STD-Y
STD-Z
RMSE-X
RMSE-Y
RMSE-Z
pm/pixel
of CHK+TIE points (mm)
at CHK points (mm)
10
87
0
90
10
0
1.20/0.43
0.291
0.558
0.251
N.A.
N.A.
N.A.
11
87
0
80
10
26 (1)
0.65/0.23
0.187
0.307
0.161
N.A.
N.A.
N.A.
12
87
0
80
44
26 (1)
0.64/0.23
0.185
0.304
0.159
N.A.
N.A.
N.A.
13
44
43
80
10
25 (1)
0.64/0.23
0.188
0.312
0.163
0.280
0.498
0.201
14
10
77
80
10
27 (1)
0.61/0.22
0.196
0.318
0.173
0.499
1.048
0.501
15
167
-
free
10
30 (I)
0.59/0.21
0.174
0.283
0.151
N.A.
N.A.
N.A.
Table 2. Absolute accuracy test of K750i.
Ver
GCP/CHK/TIE
APs
Rej
SigmaO
STD
RMSE
: Version number
: Number of control points / independent check points / tie points, respectively
: Number of additional parameters
: Rejected rays by data-snooping, rejection rule for (l) : reject all residuals >= 4xSigmaO
: Standard deviation of image observations a posteriori
: Average theoretical precision values of CHK/TIE/GCP coordinates
: Empirical accuracies of CHK/GCP coordinates.
Ver
GCP
CHK
TIE
APs
Rej
SigmaO
STD-X
STD-Y | STD-Z
RMSE-X
RMSE-Y
RMSE-Z
pm/pixel
of CHK+TIE points (mm)
at CHK points (mm)
21
87
0
99
10
0
0.55/0.25
0.165
0.312
0.139
N.A.
N.A.
N.A.
22
44
43
99
10
0
0.52/0.24
0.157
0.286
0.133
0.449
0.617
0.225
23
10
77
99
10
0
0.50/0.23
0.161
0.284
0.140
0.701
0.816
0.203
24
186
-
free
10
0
0.47/0.21
0.144
0.250
0.120
N.A.
N.A.
N.A.
Table 3. Absolute accuracy test of N93 (image acquisition on 6 th February, 2007).
Ver
GCP
CHK
TIE
APs
Rej
SigmaO
STD-X
STD-Y
STD-Z
RMSE-X
RMSE-Y
RMSE-Z
pm/pixel
of CHK+TIE points (mm)
at CHK points (mm)
31
87
0
92
10
0
0.59/0.27
0.114
0.203
0.094
N.A.
N.A.
N.A.
32
44
43
92
10
0
0.55/0.25
0.104
0.181
0.084
0.298
0.369
0.221
33
10
77
92
10
0
0.47/0.21
0.100
0.168
0.085
0.501
0.421
0.443
34
179
-
free
10
0
0.44/0.20
0.083
0.140
0.067
N.A.
N.A.
N.A.
Table 4. Absolute accuracy test of W100.
Ver
GCP
CHK
TIE
APs
Rej
SigmaO
STD-X
STD-Y | STD-Z
RMSE-X
RMSE-Y
RMSE-Z
pm/pixel
of CHK+TIE points (mm)
at CHK points (mm)
41
87
0
81
10
0
0.27/0.10
0.048
0.084
0.041
N.A.
N.A.
N.A.
42
44
43
81
10
0
0.27/0.10
0.047
0.082
0.040
0.076
0.125
0.058
43
10
77
81
10
0
0.26/0.10
0.049
0.084
0.043
0.097
0.144
0.134
44
168
-
free
10
0
0.25/0.09
0.043
0.074
0.037
N.A.
N.A.
N.A.
Table 5. Absolute accuracy test of F828.
732