Retrodigitalisierung Logo Full screen
  • First image
  • Previous image
  • Next image
  • Last image
  • Show double pages
Use the mouse to select the image area you want to share.
Please select which information should be copied to the clipboard by clicking on the link:
  • Link to the viewer page with highlighted frame
  • Link to IIIF image fragment

The role of digital components in photogrammetric instrumentations

Access restriction

There is no access restriction for this record.

Copyright

CC BY: Attribution 4.0 International. You can find more information here.

Bibliographic data

fullscreen: The role of digital components in photogrammetric instrumentations

Monograph

Persistent identifier:
830281363
Title:
The role of digital components in photogrammetric instrumentations
Sub title:
symposium of Torino, Italy ; 2nd - 4th October 1974
Scope:
ca. 200 Seiten in getrennter Zählung
Type of content:
Konferenzschrift
DOI:
10.14463/GBV:830281363
Year of publication:
1974
Place of publication:
Torino, Italy
Publisher of the original:
[Verlag nicht ermittelbar]
Identifier (digital):
830281363
Illustration:
Illustrationen, Diagramme
Signature of the source:
T 15 B 1280
Language:
English
Additional Notes:
Literaturangaben
Other Title:
Nebentitel: Digital components in photogrammetric devices
Usage licence:
Attribution 4.0 International (CC BY 4.0)
Corporations:
International Society for Photogrammetry
Commission
2
Adapter:
International Society for Photogrammetry, Commission, 2
Founder of work:
International Society for Photogrammetry, Commission, 2
Other corporate:
International Society for Photogrammetry, Commission, 2
Publisher of the digital copy:
Technische Informationsbibliothek Hannover
Place of publication of the digital copy:
Hannover
Year of publication of the original:
2015
Document type:
Monograph
Collection:
Earth sciences

Chapter

Title:
"Software Concepts for the Analytical Plotter". G. Konecny
Document type:
Monograph
Structure type:
Chapter

Chapter

Title:
[Paper]
Document type:
Monograph
Structure type:
Chapter

Contents

Table of contents

  • The role of digital components in photogrammetric instrumentations
  • Cover
  • ColorChart
  • Title page
  • [Vorwort]
  • [Inhaltsverzeichnis]
  • TRENDS IN DESIGN OF DIGITAL EQUIPMENT FOR PHOTOGRAMMETRIC INSTRUMENTS. U. V. Helava
  • "Software Concepts for the Analytical Plotter". G. Konecny
  • [Paper]
  • [Folien]
  • MODERN COORDINATE REGISTRATION SYSTEMS FOR PHOTOGRAMMETRIC INSTRUMENTS USED IN THE SOVIET UNION [Modern digital coordinate recorders for photogrammetric plotters]. G. A. Zotov, A. M. Zhilkin
  • FROM DIGITAL COMPONENTS TO INTEGRATED SYSTEMS IN PHOTOGRAMMETRY. B. Makarovic
  • On photogrammetric distortion. Horst Schöler
  • PROGRAMME UND INTERFACE FÜR RECHNERGESTÜTZTE ANALOGAUSWERTUNG. E. Dorrer, R. Schwebel
  • Analytical Photogrammetric Positioning System (APPS). Kent T. Yoritomo
  • CARTOGRAPHIC UTILITY OF SPACE PHOTOGRAPHS [Orthography from space]. Frederick J. Doyle
  • OFF-LINE ORTHOPHOTO PRINTER. Frank Scarano, Anthony Jeric
  • Program developments for the Analytical Plotter AP/C-3 at the Technical University of Hannover. H. Rüdenauer
  • Use of the Analytical Plotter AP/C-3 for point transfer. E. Keune
  • ELENCO DEFINITIVO DEI PARTECIPANTI
  • Cover

Full text

4 
The use of second generation computers made several 
simplifications possible. 
1. Due to core memory it was now not necessary to time 
optimize the program 
2. This facilitated the use of floating point 
routines, if time was not of extreme importance. 
3. Assemblers which were easier to compose for core 
computers were available for more efficient 
assembler programming . 
4. New fast access storage devices such as the 
magnetic disk could easily be added relieving the 
problem of limited memory, working with overlays . 
be) Another approach 
was of course to overcome the limitations of the 
existing computer 
by building an interface to a large third generation computer. 
This was carried out for the AP/C installation at the University 
of New Brunswick from 1968 to 1970. 
This version 2 of the AP/C was equipped with a Bendix 
AP/C computer and with additional controls to the zoom 
optic for rotation and magnification. 
The advatages of k third generation computer, such as the 
IBM 360/50 wer* obvious: 
They consisted in 
1. floating point hardware 
2. higher speed 
3. larger storage 
4. the large possibility of fast storage and I/O devices
	        

Cite and reuse

Cite and reuse

Here you will find download options and citation links to the record and current image.

Monograph

METS MARC XML Dublin Core RIS Mirador ALTO TEI Full text PDF DFG-Viewer OPAC
TOC

Chapter

PDF RIS

Image

PDF ALTO TEI Full text
Download

Image fragment

Link to the viewer page with highlighted frame Link to IIIF image fragment

Citation links

Citation links

Monograph

To quote this record the following variants are available:
DOI:
Here you can copy a Goobi viewer own URL:

Chapter

To quote this structural element, the following variants are available:
Here you can copy a Goobi viewer own URL:

Image

To quote this image the following variants are available:
Here you can copy a Goobi viewer own URL:

Citation recommendation

The Role of Digital Components in Photogrammetric Instrumentations. [Verlag nicht ermittelbar], 1974.
Please check the citation before using it.

Image manipulation tools

Tools not available

Share image region

Use the mouse to select the image area you want to share.
Please select which information should be copied to the clipboard by clicking on the link:
  • Link to the viewer page with highlighted frame
  • Link to IIIF image fragment

Contact

Have you found an error? Do you have any suggestions for making our service even better or any other questions about this page? Please write to us and we'll make sure we get back to you.

What is the fourth digit in the number series 987654321?:

I hereby confirm the use of my personal data within the context of the enquiry made.