Retrodigitalisierung Logo Full screen
  • First image
  • Previous image
  • Next image
  • Last image
  • Show double pages
Use the mouse to select the image area you want to share.
Please select which information should be copied to the clipboard by clicking on the link:
  • Link to the viewer page with highlighted frame
  • Link to IIIF image fragment

Proceedings of the Symposium on Global and Environmental Monitoring (Part 1)

Access restriction

There is no access restriction for this record.

Copyright

CC BY: Attribution 4.0 International. You can find more information here.

Bibliographic data

fullscreen: Proceedings of the Symposium on Global and Environmental Monitoring (Part 1)

Multivolume work

Persistent identifier:
856665355
Title:
Proceedings of the Symposium on Global and Environmental Monitoring
Sub title:
techniques and impacts ; September 17 - 21, 1990, Victoria Conference Centre, Victoria, British Columbia, Canada
Year of publication:
1990
Place of publication:
Victoria, BC
Publisher of the original:
[Verlag nicht ermittelbar]
Identifier (digital):
856665355
Language:
English
Document type:
Multivolume work

Volume

Persistent identifier:
856669164
Title:
Proceedings of the Symposium on Global and Environmental Monitoring
Sub title:
techniques and impacts; September 17 - 21, 1990, Victoria Conference Centre, Victoria, British Columbia, Canada
Scope:
XIV, 912 Seiten
Year of publication:
1990
Place of publication:
Victoria, BC
Publisher of the original:
[Verlag nicht ermittelbar]
Identifier (digital):
856669164
Illustration:
Illustrationen, Diagramme, Karten
Signature of the source:
ZS 312(28,7,1)
Language:
English
Usage licence:
Attribution 4.0 International (CC BY 4.0)
Editor:
International Society for Photogrammetry and Remote Sensing, Commission of Photographic and Remote Sensing Data
Publisher of the digital copy:
Technische Informationsbibliothek Hannover
Place of publication of the digital copy:
Hannover
Year of publication of the original:
2016
Document type:
Volume
Collection:
Earth sciences

Chapter

Title:
[THP-1 HIGH SPECTRAL RESOLUTION MEASUREMENT]
Document type:
Multivolume work
Structure type:
Chapter

Chapter

Title:
Analysis of Airborne Imaging Spectrometer Data: FLI and AVIRIS Image Comparisons. J. R. Freemantle and J. R. Miller
Document type:
Multivolume work
Structure type:
Chapter

Contents

Table of contents

  • Proceedings of the Symposium on Global and Environmental Monitoring
  • Proceedings of the Symposium on Global and Environmental Monitoring (Part 1)
  • Cover
  • PREFACE
  • ISPRS COMMISSION VII MID-TERM SYMPOSIUM SPONSORS
  • ISPRS COMMISSION VII MID-TERM SYMPOSIUM HOST COMMITTEE
  • ISPRS COMMISSION VII MID-TERM SYMPOSIUM EXECUTIVE COUNCIL
  • ISPRS COMMISSION VII 1988-92 WORKING GROUPS
  • TABLE OF CONTENTS VOLUME 28 PART 7-1
  • [TA-1 OPENING PLENARY SESSION]
  • [TP-1 GLOBAL MONITORING (1)]
  • [TP-2 SPECTRAL SIGNATURES]
  • [TP-3 OCEAN/COASTAL ZONE MONITORING]
  • [TP-4 SOILS]
  • [TP-5 DATA STABILITY AND CONTINUITY]
  • [WA-1 KNOWLEDGE-BASED TECHNIQUES/ SYSTEMS FOR DATA FUSION]
  • [WA-2 AGRICULTURE]
  • [WA-3 DEMOGRAPHIC AND URBAN APPLICATIONS]
  • [WA-4 GLOBAL MONITORING (2)]
  • [WA-5 WATER RESOURCES]
  • [WP-1 ADVANCED COMPUTING FOR INTERPRETATION]
  • [WP-2 LAND USE AND LAND COVER]
  • [WP-3 FOREST INVENTORY APPLICATIONS]
  • [WP-4 INTERPRETATION AND MODELLING]
  • [WP-5 LARGE SHARED DATABASES]
  • [THA-1 SECOND PLENARY SESSION]
  • [THP-1 HIGH SPECTRAL RESOLUTION MEASUREMENT]
  • AIRBORNE IMAGING SPECTROMETER DATA ANALYSIS APPLIED TO AN AGRICULTURAL DATA SET. K. Staenz and D. G. Goodenough
  • Analysis of Airborne Imaging Spectrometer Data: FLI and AVIRIS Image Comparisons. J. R. Freemantle and J. R. Miller
  • ARTIFICIAL INTELLIGENCE FOR ANALYSIS OF IMAGING SPECTROMETER DATA. F. A. Kruse
  • The Ramifications of Sampling Methods for Imaging Spectrometers. J. Douglas Dunlop & John R. Miller
  • SPECTRAL VARIABILITY EFFECTS ON THE ATMOSPHERIC CORRECTION OF IMAGING SPECTROMETER DATA FOR SURFACE REFLECTANCE RETRIEVAL. P. M. Teillet and J. R. Irons
  • EVALUATION OF ATMOSPHERIC EFFECTS IN HIGH SPATIAL/SPECTRAL RESOLUTION AIRBORNE IMAGERY. D. WilliamsO'Neill, N. T., A. Royer, Miller J. R., J. Freemantle
  • OPTIMIZATION OF UNSUPERVISED LEARNING FOR HIGH RESOLUTION REMOTE SENSING DATA. SHIMODA,HARUHISA; MATSUMAE,YOSHIAKI; NATENOPPARATH,AMNARJ; FUKUE,KIYONARI; SAKATA,TOSHIBUMI
  • [THP-2 GIS INTEGRATION]
  • [THP-3 ENVIRONMENTAL IMPACT ASSESSMENT]
  • [THP-4 MICROWAVE SENSING]
  • [THP-5 IMAGE INTERPRETATION AND ANALYSIS]
  • [FA-1 TOPOGRAPHIC ANALYSIS]
  • [FA-2 GLOBAL MONITORING (3)]
  • [FA-3 FOREST DAMAGE]
  • Cover

Full text

INTRODUCTION 
Myperspectral data presents interesting 
opportunities and challenges to researchers, not 
the least of which is the problems associated 
with displaying and manipulating imagery with 
over 200 channels and 16 bit resolution. The FLI 
has 288 spectral bands from 0.43 to 0.805 
microns and the AVIR1S has 224 spectral 
channels from 0.4 to 2.5 microns. The AVIRIS 
data also can be obtained spectrally-resampled 
to 210 channels. Most commercial image 
processing packages do not support imaging 
spectrometery sensors at their full spectral and 
radiometeric resolution. At the Institute for 
Space and Terrestrial Science (ISTS) we have 
developed an Imaging Spectrometer Analysis 
Package for the quantitative analysis of full 
resolution imaging spectrometery data. This work 
grew from a cooperative project between York 
University and Moniteq Ltd. to study data from 
the Canadian Fluorescence Line Imager (FLI) 
(Miller et al., 1987). 
IMPLEMENTATION 
At ISTS, software has been written to analyze 
imaging spectrometer data from the FLI and 
from NASA’s Airborne Visible/Infrared Imaging 
Spectrometer (AVIRIS) at full spectral, spatial 
and radiometeric resolution. The only limitation 
being the availability of disk space to store the 
very large volume of data: 16 MB for a typical 
FLI full spectral scene and 120 MB for a full 
AVIRIS scene. The image is usually subset to a 
more manageable size for analysis. The Imaging 
Spectrometer software is integrated into PCI’s 
EASI/PACE image analysis system using the 
Software Toolbox (PCI, 1989a). Imaging 
spectrometery data is stored consistent with the 
PCIDSK format (PCI, 1989b). Currently the 
software runs on a Microvax II, Sun workstation 
(SUN 3/60) and a PC based image processing 
workstation. 
A modular approach was taken to the software 
development. Instead of independent systems for 
batch and interactive processing of the imagery, 
one library of fundamental subroutines was used 
(see Figure 1) to which all modules are linked. 
In the interactive mode, FORTRAN modules 
were strung together by an EASI procedure 
(command file). This allows new analysis 
modules to be incorporated easily and permits 
each module to be run independently if the need 
arises. In the batch mode one large FORTRAN 
programme is used that does all the processing 
tasks. 
I'he first step in the analysis procedure, whether 
it be batch or interactive, is to select and 
calibrate the data. A tablet (or mouse) is used to 
define a window of interest from the displayed 
image for interactive processing. The average 
digital value for the window is calculated. For 
batch processing an image database input 
window is specified and calculations are done on 
a pixel by pixel basis. The data must be 
calibrated to appropriate units and for this 
purpose the software allows several options. 
Calibration files are stored for spectral, 
radiometric and reflectance calibration. 
Conversion to radiance is done using radiance 
scale factors supplied by the sensor’s 
manufacturer. One useful option is to employ a 
table of extra-terrestrial solar irradiance values 
and the image geometry to convert the image to 
pseudo-reflectance values. An approximate 
atmospheric correction procedure can be applied 
if ground measurements of suitable reflectance 
targets are supplied and a 
digital-number-to-reflectance calibration is 
available. If a Digital Terrain Model (DTM) is 
available a correction for topography can be 
made. The analyst determines which calibration 
procedure is to be used. 
Interpretation algorithms or inverse models can 
now be applied to calibrated data. These 
algorithms can extract spectral and/or 
reflectance parameters such as reflectance ratios, 
watercolour parameters (Freemantle and Miller, 
1987) or vegetation red edge spectral parameters 
(Miller et al., 1990b). In the interactive mode the 
calculated parameters and spectral curves are 
displayed at the workstation terminal for the 
analyst to assess (see Figure 2). The 
EASI/PACE parameter file stores interpretation 
choices, for example the vegetation red edge 
spectral window, for use during batch processing 
of the image. During batch processing user 
selected calculated parameters are written back 
to a PCIDSK image database in 8 bit form. This 
image can be then analyzed using conventional 
methods such as thresholding, pseudo-colour, 
etc. The modular approach allows new 
interpretation, atmospheric correction or 
calibration models to be added to the software 
with a minimum of effort. 
APPLICATION 
The Imaging Spectrometery Analysis Package 
has been used to analyze AVIRIS and FLI data 
over vegetated targets (Miller et al. 1990, Rock 
et al., 1990). The red edge analysis can be 
applied to both the FLI and AVIRIS data (see
	        

Cite and reuse

Cite and reuse

Here you will find download options and citation links to the record and current image.

Volume

METS METS (entire work) MARC XML Dublin Core RIS Mirador ALTO TEI Full text PDF DFG-Viewer OPAC
TOC

Chapter

PDF RIS

Image

PDF ALTO TEI Full text
Download

Image fragment

Link to the viewer page with highlighted frame Link to IIIF image fragment

Citation links

Citation links

Volume

To quote this record the following variants are available:
Here you can copy a Goobi viewer own URL:

Chapter

To quote this structural element, the following variants are available:
Here you can copy a Goobi viewer own URL:

Image

To quote this image the following variants are available:
Here you can copy a Goobi viewer own URL:

Citation recommendation

Proceedings of the Symposium on Global and Environmental Monitoring. [Verlag nicht ermittelbar], 1990.
Please check the citation before using it.

Image manipulation tools

Tools not available

Share image region

Use the mouse to select the image area you want to share.
Please select which information should be copied to the clipboard by clicking on the link:
  • Link to the viewer page with highlighted frame
  • Link to IIIF image fragment

Contact

Have you found an error? Do you have any suggestions for making our service even better or any other questions about this page? Please write to us and we'll make sure we get back to you.

What color is the blue sky?:

I hereby confirm the use of my personal data within the context of the enquiry made.