Table N. 1
CENTRE
Required
photographic
material
Method
of
triangulation
Instrument
Test
Number
of points
used
for
adjustment
Method
of
adjustment
Date of sending
material
to the Centres
Date of
beginning
measurements
Date of close
of
measurements
Date of close
of
calculations
Date of
sending
adjusted
coordinates
to the Presidency
Date of
sending
discrepancies
on control points
to the Centres
Wild RC7
Analogical
Wild A7
1
7
second degree
2
11
second degree
April 15, 1960
June 1960
August 16, 1961
December 7, 1961
December 14,1961
November 1962
3
15
second degree
4
7
third degree
National Research Council
Analytical
ТАЗ
5
8
second degree
Ottawa - Canada
6
16
second degree
May 9, 1961
Sept. 20, 1961
December 12,1961
December 14,1961
November 1962
7
8
third degree
Analytical
Zeiss 18 X 18
8
8
second degree
9
12
second degree
March 15, 1960
June I, 1960
July 20, 1960
July 21, 1960
November 1962
10
16
second degree
SOM Aquilor
Analogical
В-P Pow.
11
4 plan.
stereotemplet
January 25, 1960
April 20, 1960
May 20, 1960
April 4, 1962
May 17, 1962
24 altim.
mechanical
12
24 altim.
mechanical
January 25, 1960
April 20, 1960
June 10, 1960
April 4, 1962
May 17, 1962
13
9
IBM 704
January 25,1960
April 20, 1960
August 2, 1960
April 4, 1962
May 17, 1962
Institut Géographique National
Paris - France
Analytical
ТАЗ
14
9
IBM 7090
June 20, 1960
Sept. 10, 1960
December 12,1961
April 4, 1962
May 17, 1962
Analytical
SOM-Stereo-
15
9
IBM 7090
June 5, 1961
July 24, 1961
January 15, 1962
April 4, 1962
May 17, 1962
comparator
Zeiss RMK
Analytical
ТАЗ
16
9
IBM 7090
Sept. 28, 1960
December 18,1960
January 28,1962
April 4, 1962
May 17, 1962
The Ohio State University
Wild RC7
Analogical
Wild A7
17
46
graphical-
April 15, 1960
July 1, 1960
December 5, 1961
March 26, 1962
March 28, 1962
May 14, 1962
Columbus-Ohio - U.S.A.
numerical
The University of Illinois
Zeiss RMK
Analogical
Wild A7
18
38
Zeller-method
Nov. 16, 1961
December 18, 1961
January 3, 1962
April 20, 1962
April 23, 1962
May 17, 1962
Urbana-Ill. - U.S.A.
International Training Centre
SOM Aquilor
Analytical
Wild-Stereo-
19
10 plan.
Jerie
January 16,1961
June 19, 1961
July 22, 1961
July 1, 1962
July 5, 1962
July 16, 1962
Delft - Holland
comparator
30 altim.
German Centre including 7
different Institutes:
T. Universität - Berlin
T. Hochschule - München
I. A. G. - Frankfurt
T. H. - Stuttgart
Zeiss RMK
Analogical
Zeiss C8
20
33
only strips
December 16,1959
June 1960
April 1962
July 1962
July 31, 1962
August 21, 1962
Geodätisches Inst. d. Tech. Hoch.
adjustment
- München
Zeiss Aerotopograph - München
Plan & Karte - Münster