N
lechanical
id Method
dr'jjm PARTIAL CALIBRATION
of a Stereoscopic Optical - Mechanical
201- Projection Instrument Grid Method
Right Projector
c = 150mm z »300 mm
Radial Distortion
s¿ 14 2.8 3.5 5.2 5.6 5.9 5.0 4.5 6.1 (4.5) pm
Fig. 4.21: 32. Partial calibration of projector. The dashed curve
t represents the radial distortion according to a polynomial of
1SV tan =8.1pm fifth order.
Fig. 4.21: 34. Cf. Fig. 4.21: 32.
Right Projector
Residuals after Adjustment
z - 2c
RMSVres = 5.3pm RMSV rad -5.4pm RMSV tan «5.2 pm
Right Projector
Residuals after Adjustment
z - 2.5c
RMSV =6.5 urn RMSV “6.9 pm RMSV. -6.1pm
res r rad tan r