Full text: Actes du onzième Congrès International de Photogrammétrie (fascicule 3)

Table 9• An example of the values of the adjustment in an A7 autograph (z - 300 mm). 
24 
Point or 
Readings 
Corrections 
Settings to 
Action 
Control- 
element 
the scales 
readings 
x 5 
500.200 mm 
dt = 50 pm 
500.300 mm 
moving the floating mark 
500.300 ram 
y 5 
50C.300 « 
dl = 50 ” 
500.200 " 
over point 5 with the 
adjusting screws of the 
objective 0 p . 
500.200 " 
*5 
500.300 mm 
dXp=-100 pm 
500.100 mm 
moving the picture carrier 
500.100 ram 
500.200 n 
dy p = 25 " 
500.250 w 
support with the adjusting 
screws ^ until the floating 
500.250 " 
mark reaches point 5. 
c 
150.000 mm 
dc = -100pm 
149.900 mm 
loosening the grub screws, 
turning the principal 
distance drum until 150.000 
ram is read( without the 
spindle turning) and 
tightening the grub screws. 
150.000 ran 
¥ 
loofboo 
0 
0 
R 
LTV 
II 
100 §35 5 
loosening the grub screws, 
loofboo 
CO 
100 §000 
=-400 GG 
99§960 
setting to 100§000 (without 
the spindle turning) and 
tightening the grub screws. 
100§000 
bx 
0.000 mm 
dbxs=-100 pm 
base out 
loosening the grub screws, 
0.000 mm 
0.100 ram 
setting to 0.000 ram 
by 
0.000 11 
dby*= 200 n 
11 
H 
& 
(without the spindle 
0.000 « 
0.200 ” 
turning) and tightening 
bz 
0.000 ” 
dbz= 100 « 
bZi = 
99.900 " 
the grub screws. 
0.000 " 
see Instructions for Wild A7-
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.