33
3« The measurements shall be made on axis and at 15°
each side of axis, in the horizontal.
4. The scanning direction shall be both radial and
tangential.
5« The measurements shall be performed in a narrow
spectral region centered on 546 nm, transmission
of the filter to be indicated. If possible, meas
urements shall also be made using a broader spectral
region approximately fitting the spectral response
of an ’'extended-red 1 ' panchromatic emulsion including
a Wratten 21 filter, (e.g. Eastman Kodak emulsions
such as Plus X Aerographic, which have approximately
uniform sensitivity from 500 to 700 nm)• A sheet of
Wratten 21 filter is enclosed with the lens. A curve
showing the actual spectral sensitivity used shall be
provided with the test results.
6. The measurements shall be made in planes 0.1 mm apart,
referenced to the plane giving a maximum value for the
transfer function at 40 lines/mm on axis.
7. The measurements shall be made at spatial frequencies
up to the limit which is convenient with the apparatus,
preferably to 300 lines per mm on axis.
8. An estimate of the accuracy of the measurements and a
discussion of the relevant factors would be of value.