Summary 
The invention of the Analytical Plotter by HErAvA has provided practical photogrammetry with a 
new aid the importance of which is constantly growing due to the development of digital techniques. 
The equipment presently available ranges from the AP/C-3 by O.M.L to systems with automatic image 
correlation (AS 11-BX by Bendix, Unamace by Bunker-Ramo and Gestalt by Hobrough). The effi- 
ciency of an Analytical Plotter is equally determined by the hardware (core-storage capacity. periphe- 
ral equipment) and the software. While the advantage of the Analytical Plotter was originallv consi- 
dered to be the possibility of increased plotting accuracy due to analytical correction of systematic 
image errors and while its importance for special plotting projects (military panoramic photography) 
was recognized very soon, its value is presently increasing due to its particular suitability for automat- 
ing photogrammetric techniques, at least on a step-by-step basis: the semi-automation of the orientation 
processes, the automatic positioning of points, the use of output media susceptible to automation. 
The efficiency of the Analytical Plotter will increase bv comparison with that of conventional equip- 
ment if the instrument is programmed for certain specific tasks: for example. as an aerotriangulator 
with semi-automatic point transfer, as a digital data-acquisition system or as a terrestrial plotter cap- 
able of making allowance for special photographic and object conditions. 
Résumé 
La création de l'Analytical Plotter par HELAvA a fourni à la pratique de la photogrammétrie un 
nouvel appareil qui, vu l'essor de la technique digitale. prend de nlus en nine d’imnartance. Les nlot- 
ters analytiques disponibles à l'heure actuelle s'étendent du modèle AP/C-3 de O.M.T. aux systèmes 
à corrélation automatique des images (AS 11-BX de Bendix, Unamace de Bunker-Ramo, Gestalt de 
Hobrough). Le rendement d’un plotter analytique dépend en premier lieu du hardware (capacité 
de la mémoire à tores magnétiques, unités périphériques), mais pas moins du software. Initialement, 
on avait considéré comme avantage essentiel du plotter analytique la possibilité d’ obtenir une meil- 
leure précision à la restitution par la correction analytique des aberrations systématiques, puis on avait 
reconnu sa supériorité pour des travaux de restitution spéciaux, p.ex. prises de vue panoramiques 
militaires. Aujourd'hui. le plotter analytique gagne en signification, du fait qu'il se préte à l'automa- 
tisation des méthodes photogrammétriques. tout au moins pour leurs phases: opérations d'oriente- 
ment semi-automatiques, pointé automatique des points, emploi d'unités de sortie automatisables. Le 
plotter analytique fait preuve de performances qui dépassent celles des appareils conventionnels, 
lorsqu'il est programmé pour certains travaux. p.ex. comme appareil d'aérotriangulation avec report 
semiautomatique des points d'appui, comme unité d'acquisition digitale de données ou comme appa- 
reil stéréorestituteur terrestre susceptible de s'adapter à des conditions particulières de prise de vue 
et à la configuration des objets. 
Schrifttum 
|1] HErava, U.V.: New Principle for Photogrammetric Plotters, Phia (1057-38) 89-96 
(2[ INCHILLER: et al.: The Galileo D.S. Digital Stereocartograph, kommission I. IGP Kongreß, Ottawa 1972 
[3] HELavA, L.V.: Analytical Plotter, Can. Surv. (1963 ) 131-148 
[4] Lesser. B. 5.: General Concept of the Analytical Plotter, Can. Surv. (1963) 168-182 
[5] Parent, Go: Analysis of the Mechanical-Optical Design of the Analytical Plotter, Can. Surv. (1963) 148-154 
[6] Jousow, E. C. und Kamu. V. C.: Computer and Programs for the AP/C Analytical Stereoplotter, Can. 
Surv. (1963) 155-168 
[7] Koxecny, G.: The Analy tical Plotter AP-2C and its Interfacing with an IBM 360-50 System, BuL 36 (1968) 
107-116 
[8] Kaww, V. C. et al.: Design of the BX 272 integrated-circuit control computer, IGP KongreD 1968, Kommis- 
soin lI 
[9] FRIEDMANN, J.3., Masry, S. E.. kRAKIWSKY, M. E; The New Analytical Plotter Proceedings: Discussions on 
Man-Machine Interface in Photogrammetry, University of New Brunswick, Kanada Dept. of Surveying 
Engineering, (1972) 45-63 
[10] Forrest. R. B.: Photogrammetric Research Facility, ASP 1974, St. Louis 
[11] BERTRAM. 5.: The Universal Automatic Map Compilation Equipment, Phm. Eng. 30 (1964) 
[12] HEtava. U. V.. WurrESIDF, A. E.. MaruERLy, ©. Wi: New Automatic Analytical Stereoplotter, IGP 
Kongreß 1968, Kommission I 
[13] HeLava. U. V.. CirAPELLE. W. E.: Epipolar Scan Correlation, Bendix Techn. Journ. 19-23 5 (1972) 
[14] Seymour, R. H. and WiuTESIDE, À. E.: A new on-line Computer Assisted Stereocomparactor, ASP 1974, 
— 
St. Louis 
[15] Honnovcir, G. L. and Hosrot cir. T. B.: Image Correlator Speed Limits, Bul, 39 (1971) 20-24 
[16] Konzcny, G.: Software Concepts for the Analytical Plotter, Symposium der Kommission I. IGP. Turin 
1974 
[17] Keune. E.: Aerotriangulation of the Analytical Plotter, Symposium Turin 1974 
[18] RÜDENAUER. H.: New AP/C-3 Programms, Symposium Turin 1974 
 
	        