Report of Commission I, Optical and Modulation Transfer Working Group
Clarice L. Norton, Chairman
Gerald C. Brock and Dr Roy Welch
Abstract
The Optical and Modulation Transfer Functions Working Group has
been concerned with updating Section 6 of "Procedures for Calibrating
Photogrammetric Cameras and Related Optical Tests." As presently
proposed, it is expanded to include guidelines for MTF analysis
techniques of camera systems. The revision is printed in full.
The status of OTF/MIF standards in various nations is reviewed
and there is a report of current testing results performed by the
SIRA group on a photogrammetric wide field lens which shows good
correlation among laboratories.
The application of MTF technique in the analysis of aerial and
space photography has proved a reliable evaluation of the quality
of operational systems when control targets are lacking. The results
are reported.
A study by the U. S. Air Force shows the reliability and feasi-
bility of employing edge gradient techniques in control of performance
of aerial photographic systems.
This working group report also contains a short summary of current
papers and meetings on the subject of image quality using OTF and
MIF evaluation techniques and makes recommendations for further study.