PP/I
38
derived for the shape of the
MTF-curve. This enables two or
three numbers to be substitut
ed for the function and makes
possible the correction of the
resolution criteria with the MTF.
The pre-indication of aerial photo
graph quality is done by using
transparent sketches of MTF
curves for the lens, the image
displacement and the aerial film
threshold contrast curves. These
curves are obtained by means
of Fevensky’s test object which
has continually changing spatial
frequencies and light distribu
tion.
tifs sont proposées pour les
fréquences N = 10 mm' 1 et N =
20 mm' 1 .
On arrive à une formule ap
prochée pour la forme de la
courbe de la caractéristique à
contraste de fréquence. Elle
permet de remplacer la fonction
par deux ou trois nombres. Cela
donne la possibilité d’établir la
corrélation du critère du pouvoir
séparateur et de la caractéristi
que à contraste de fréquence
MTF.
Le pronostic de la qualité des
aérophotographies est effectué
à l’aide de marques transparentes
suivant les courbes des carac
téristiques à contrastes de fré
quences pour les objectifs, les
caractéristiques à contrastes de
fréquence du filé et des courbes
de seuil des émulsions aéropho
tographiques. On obtient ces
courbes en utilisant la mire
Fivénski qui change les con
trastes et les fréquences spa
tiales sans discontinuer.
fizienten der Kontrastübertra
gungsfunktion bei den Frequen
zen N = 10 mm-1 und N = 20 mm-i
vorgeschlagen.
Für die verwendete Kontrast
übertragungsfunktion werden
Näherungsformeln abgeleitet,
mit deren Hilfe man durch
Substitution von 2 oder 3 Ziffern
die Beurteilung des Auflö
sungsvermögens mit der Kon
trastübertragungsfunktion ver
binden kann.
Die Qualitätsprüfung der Luft
bilder erfolgt mit transparenten
Zeichnungen der Kontrastüber
tragungsfunktionen der Objek
tive, der Bildwanderung und der
Kurven des Kontrast-Schwellen
wertes. Diese Kurven erhält
man mit Hilfe des Fevensky-
Testgerätes, bei dem be
stimmte Frequenzen und der
Kontrast verändert werden
können.
14 Gerencsér, M.
Hungary
Automated Edge Gradient Analysis (EGA) for testing photogrammetric systems
Automatisation d’analyse de la périphérie pour évaluer des systèmes de caméras photogrammétriques
Automatische Kantenbildanalyse (KA) zur Prüfung photogrammetrischer Aufnahmesysteme
For exploiting the potential of
MTF’s for practical image evalu
ation, an automatic EGA has
been developed for entire photo
grammetric system which
operates in a frequency range
from 0 to 50 cy/mm. The work it
self has consisted of the fol
lowing main parts:
1. The Schnell photometer Type
G II, (Zeiss Jena) has been
equipped with an analog di
gital converter, tape punch,
and keyboard for digital re
cording of step wedge copies,
edge targets, and identifiers.
Compared with earlier analog
recording in a scale of m =
375:1 the length measuring
capability of the instrument
has been increased a full
order of magnitude, and has
been made equivalent with
the mechanical accuracy of
the measuring screw.
2. A converting program as
sures the compatibility of
the microphotometer out
puts with the ICL System 4-70
Computer used for data pro
cessing.
Une automatisation d’analyse du
pourtour de la vue a été déve
loppé par l’auteur afin d’utiliser
la FTM pour l’évaluation pratique
des photogrammes. La zone de
service du système s’étend de
0 à 50 cycle/mm.
Le développement consiste en
la digitalisation du procédé de
mesure ainsi que les program
mes pour l’ordinateur. Le pro
gramme donne graphiquement la
fonction de dispersion et la FTM.
On peut caractériser la précision
interne du système par une dis
persion de 2 % dans la FTM,
mais l’utilisation de la fonction
périphérique (EF) diminue l’ef
fectivité de la régression, ce qui
nous éloigne de la précision
théorique.
Les test-contrôles sont en cours.
Um die Leistungsfähigkeit der
MÜF für die praktische Beuertei-
lung der Bildqualität auszu
nutzen, wurde eine automa
tisierte KA für das gesamte
photogrammetrische Aufnahme
system entwickelt, die in einem
Frequenzbereich von 0—50
cy/mm arbeitet.
Die Untersuchung selbst be
stand aus folgenden Haupt
teilen:
I.Das Schnellphotometer G II
von Zeiss Jena wurde mit ei
nem Analog-Digital-Konverter,
einem Streifenlocher und
einer Tastatur für die digitale
Registrierung der Grauwert
stufen und der Kantenbilder
ausgerüstet. Im vorliegenden
Test wurden digitale Schritte
von 1,3 jjm verwendet. Im
Vergleich zur früheren analo
gen Registrierung im Mass
stab M = 375:1 wurde die Ge
nauigkeit der Längenmessung
auf dem Film um eine ganze
Grössenordnung erhöht, so
dass sie jetzt gleich ist wie
die mechanische Genauigkeit
der Messspindeln.