targets it is possible to roto-translate all the model and geo-
reference each point of the scan.
Analysing from a metrical point of view the result obtained with
this two methodologies, with 11 points topologically estimated
it has been calculated the gap of the three coordinates. Table 5
reproduces the statistic of the coordinates difference defined
with the two methods.
Mean [em] St.Dev.[em]
X y Z X y Z
Photogrammetry | 0.0 | -0.2 | -0.3 | 1.6 | 1.6 | 1.7
Laser Scanner -0.4 | 0.1 0.1 1.8 1.2 1.5
Table 5 — Gaps statistics of the GPC coordinates surveyed with
the total station
The comments of this schedule are: firstly the number of the
points is less than the GCP used (20) because both in the laser
model than in the photogrammetric one the measure of some
points is hard (for bad resolution) instead for some one is
affected by a blunder.
The average is more restricted and shows the goodness of the
geo-reference in both of this two methods with the topographic
one. In particular about the laser scans, this shows how the
estimation of the coordinates of the artificial targets, used to
roto-translate the instrumental reference system, has been done
with excellent accuracy.
In the end the standard deviation of the difference is, for the
coordinates and in both of this cases, of the same order of the
precision of the GCP, at the confirmation of the uniformity of
the accuracy of these three survey methods.
4. TEXTURE MAPPING
The Texture mapping is the possibility to drape the picture upon
the solid model. This representation was made with the
commercial software TexCapture by NRC (National Research
Centre) of Toronto (Canada). For this application we used the
Nikon Coolpix 4300 (2300 x 1700 pixels) camera with 8 mm
of focal objective and 1/1.8 shutter.
International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences, Vol XXXV, Part B5. Istanbul 2004
TexCapture, like many digital photogrammetric software,
allows to calculate the internal and external orientation
parameters of the images and the following “ortho-projection”
upon the triangulated solid model.
During the survey we used some cunnings; the images were
acquired with the similar angle of the laser scans, using a high
resolution camera (it is important to have a CCD greater than
3.2 MPixel) and we left the same zoom in order to keep the
same camera calibrations for every texture. Actually we did not
use this mean because the calibration parameters were estimated
for each of the six shots (five on the side and one on the top).
During the calibration and orientation the parameters to define
are 15 and in particular:
6 parameters of external orientation of the camera: 3
coordinates (Xc, Yc, and Zc) of the camera projection
centre and 3 rotations of the camera (pitch, roll, and yaw);
= 3 parameters of internal orientation: principal distance and
the coordinates x and y of the principal point of the
images;
= 6 parameters of camera calibration including: 2 affined
image parameters to correct for scale difference and non-
perpendicular of the x and y image coordinates, 2 radial
lens distortion parameters (third and fifth order), and 2
decentring lens distortion parameters.
The software achieved this purpose writing a co-linearity
equations system for at least 8 homologues points, recognised
on the solid model and on the images.
For the Texture mapping of the Baptistery of Cremona, we
individualised at least 20 points of each scan, chosen in a
uniform way, not lying on the same plane. At the beginning we
estimated the 15 parameters in a combined way; subsequently,
after analysing the meaning of calibration parameters
estimation, we locked the orientation parameters and set on
zero the insignificance one. Anyway the principal distance and
the positioning of the principal point was kept at the value
estimated step by step.
After calibrating the camera the TexCapture software allowed
us to “drape” the images on the triangulated model, deleting
both the distortions due to the intrinsic characteristics of the
camera we used (objective distortion, etc.) and the prospective
distortions.
Figure 6 — Laser scans aligned a) and b) image with intensity of the laser scanner data c) solid model
492
Interne
ie ETC
As yo
solid ı
In blu
data (
zones
(Ther
autho
surve:
modu
techni
Bapti:
three
the to
Certa
thank
centir
proce
colou
COITe:
result
and tl