Full text: XVIIth ISPRS Congress (Part B5)

  
  
   
    
   
   
   
    
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
   
   
  
  
  
  
   
   
   
   
   
   
   
   
    
    
   
   
   
    
    
   
   
  
   
   
   
   
   
discrepancy is 0.1 pixel in x and 0.05 pixel in y. The re- 
sults of the bundle adjustment (version 6 in Table 2) 
show that the accuracy is only slightly degraded as com- 
pared to that of pixelsynchronous frame grabbing. This 
close agreement of the results is attributable to the high 
degree of redundancy and indicates that the accuracy is 
limited by effects other than the synchronization. The 
shear determined by the additional parameters in the 
bundle adjustment is in good agreement with the values 
computed in the analysis of the frame grabber and of sig- 
nal transmission. 
0.1 Pixel 
.— —. 
et ome AE VE, FL E US 
E e sie ak = 
re Ta” NS RR az TS Qa Es 
EE eire 
" 
Figure 16 Differences of image coordinates between 
PLL line-synchronization and pixelsynchro- 
nous sampling for 6 frames. 
The results of the two synchronization methods were fur- 
ther analyzed by using the object coordinates obtained in 
a version with minimum control and pixelsynchronous 
sampling as reference coordinates for a version of the 
PLL line-synchronization imagery with identical control. 
The RMS difference of the object space coordinates are 
0.036, 0.033 and 0.044 mm in X, Y, and Z respectively. 
The accuracy in image space is 0.11 and 0.10 pixel in x 
and y respectively. This shows that an internal precision 
of three-dimensional measurements of 0.01 pixel can be 
attained when identical illumination and imaging condi- 
tions are present. The RMS differences correspond to 1 
part in over 70000. 
3.5 Limiting Factors 
The theoretical precision estimates and the empirical ac- 
curacy measures of version 5 differ by a factor of 2 in X 
and Y and 1.5 in Z. Potential origins of this large differ- 
ence were consequently investigated. 
The precision of the reference coordinates is insufficient 
to verify this accuracy level. When correcting the theo- 
retical precision estimates for the precision of the refer- 
ence coordinates and the centricity of the targets used by 
the theodolite and CCD-cameras the difference to the 
empirical accuracy measures is decreased to factors of 
1.6, 1.4, and 1.1 in X, Y, and Z respectively. It was al- 
ready noted above that the comparison to the reference 
coordinates exhibit systematic differences (see Figure 
16). These could at least in part be attributable to effects 
of smaller local illumination gradients. This was also 
found in other studies through slight variation of the illu- 
   
mination conditions. The effects of the use of an affine 
transformation instead of a perspective transformation in 
LSM was also investigated. Considering that the average 
error will result in a shift it was concluded that the effect 
thereof can be neglected as compared to the influence of 
local illumination gradients. A further modelling with 
supplementary additional parameters (Brown, 1976 and 
Grün, 1978) was attempted but did not lead to any im- 
provement. 
It was thus concluded that the accuracy in this test was 
primarily limited by the local illumination gradients, the 
non-uniform background, the small image scale, and the 
large difference thereof. Local illumination gradients 
could be eliminated by the use of retro-reflective targets. 
The non-uniform background can be improved on by de- 
signing a larger area around the targets. The image scale/ 
target size in the imagery, i.e. the number of pixels onto 
which a target is imaged, can be improved by using larg- 
er targets and/or a camera with higher "resolution". The 
first option is not always practical. The target diameter of 
20 mm across a 2.6 m large object is already quite large 
for practical applications. This can in fact be improved 
with retro targets as their return is much better and scat- 
tering significantly increases the apparent diameter in the 
imagery. A high "resolution" camera, i.e. a camera deliv- 
ering over 1024 x 1024 pixels, would also reduce the ef- 
fects of local illumination gradients and non-uniform 
background as the area surrounding the target affecting 
the target localization is smaller. Finally the large varia- 
tion of image scale could be reduced when using a longer 
focal length than the 9 mm lens used here due to space 
restrictions. 
4 CONCLUSIONS 
The radiometric and geometric characteristics of a num- 
ber of elements involved in image acquisition with digi- 
tal imaging system have been outlined and their effects 
on the accuracy of three-dimensional photogrammetric 
measurements discussed. À number of sources leading to 
potential degradations have been located. The perfor- 
mance of off-the-shelf equipment was demonstrated with 
a three-dimensional accuracy test. It could be shown that 
accuracies of 1/85™ of the pixel spacing can be attained. 
It was found that accuracies comparable to pixelsynchro- 
nous frame grabbing can be attained with PLL line-syn- 
chronization when a highly redundant network is used. 
The limitations indicate that even higher accuracies 
should be attainable under better environmental condi- 
tions as no limitations found so far are of a fundamental 
nature. It can thus be expected that accuracies approach- 
ing the 1/100! of the pixel spacing can indeed be at- 
tained. 
5 REFERENCES 
Beyer, H.A., 1988. Linejitter and Geometric Calibration of 
CCD-Cameras. International Archives of Photogramme- 
try and Remote Sensing, Vol. 27, Part B10, pp. 315-324. 
and in: ISPRS Journal of Photogrammetry and Remote 
Sensing, 45, 1990, pp. 17-32. 
  
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.