coordinates can be obtained, if a rigorous mathematical
model including the calibration parameters is used for
the evaluation. Thus, the results show the applicability
of the camera for photogrammetric tasks. Further re-
search has to be conducted in order to
- setup an automatic calibration procedure,
- improve the accuracy of the piezo-controlled sensor
movement,
- include a radiometric calibration.
The stability over time of the orientation parameters and
the accuracy level already reached encouraged us to
design a digital photogrammetric close range measure-
ment and evaluation system around the ProgRes 3000,
in which images can be acquired, stored, and evaluated
in a totally digital data flow using rigorous photogram-
metric procedures.
S. REFERENCES
IntArchPhRS International Archives for Photogram-
metry and Remote Sensing
Interlaken Proceedings of the Intercommission
Conference on Fast Processing of
Photogrammetric Data, Interlaken, June
1987
Beyer H., 1987: Some aspects of the geometric calibra-
tion of CCD cameras, Interlaken, 68-81.
Beyer H., 1991: Untersuchungen zur geometrischen
Qualitát der Datenübertragung bei der Bildaufnah-
me mit CCD Kameras, in: Radig B. (Ed.), Musterer-
kennung 1991, 13th DAGM Symposium, Informatik
Fachberichte 290, Springer, Berlin, 328-336.
Bósemann W., Godding R., Riechmann W., 1990: Pho-
togrammetric investigation of CCD cameras,
IntArchPhRS (28) 5/1, 119-126.
Dáhler J., 1987: Problems in digital image acquisition
with CCD cameras, Interlaken, 48-59.
Edmundson K., Novak K., He G., 1991: Analytical cali-
bration of a stereo-vision system, Technical Papers
ACSM-ASPRS Annual Convention (5) 86-92.
Fórstner W., 1982: On the geometric precision of digital
correlation, IntArchPhRS (24) 3, 176-189.
Gülch E., 1984: Geometric calibration of two CCD-ca-
meras used for digital image correlation on the PLA-
NICOMP C 100, IntArchPhRS (25) A3a, 363-372.
Heipke C., Kornus W., 1991: Nonsemantic photogram-
metric processing of digital imagery - the example of
SPOT stereo scenes, in: Ebner H., Fritsch D., Heipke
C. (Eds.), Digital Photogrammetric Systems, Wich-
mann, Karlsruhe, 86-102.
Heipke C., Stephani M., Strunz G., Lenz R., 1991: Ac-
curacy potential of a digital CCD camera for photo-
grammetric applications, in: Radig B. (Ed.), Muster-
erkennung 1991, 13th DAGM Symposium, Informa-
tik Fachberichte 290, Springer, Berlin, 320-327.
Lenz R., 1987: High accuracy feature extraction using
chain code in grey value images, IBM Research Re-
port RC 56811.
Lenz R., 1989: Digitale Kamera mit CCD-Fláchensen-
soren und programmierbarer Auflósung bis zu 2994
* 2320 Bildpunkten pro Farbkanal, DAGM (11),
411-415.
Lenz R., Lenz U., 1990: Messung der Übertragungsci-
genschaften einer hochauflósenden Farbkamera mit
CCD-Flächensensor, DAGM (12), 29-35.
Luhmann T., Wester-Ebbinghaus W., 1987: On the geo-
metric calibration of digitized video images of CCD
arrays, Interlaken, 35-47.
Müller F., Stephani M., 1984: Effiziente Berücksichti-
gung geodátischer Beobachtungen und Objektinfor-
mationen in der Bündelblockausgleichung,
IntArchPhRS (25) A3a, 558-569.