6000
(3969
8875
k of base
mensional
ed which
al angle to
. Figure 2
te with the
esults are
J of the
ted out all
,e Plate
E
f Base Plate
The measurement accuracy of the total station is
+1mm which is an enough accuracy relative to an
allowable accuracy of the base placed position which is
less than £2mm.
However, because of a plural bases having the same
shape being measured, there is a great possibility of an
error occurring, for example, the same base is measured
twice or a base not measured yet exists.
Also, since a discrepancy is estimated by comparing the
measured value with the design value after end of the
measurement, occurrence of error in measurement
cannot be grasped immediately. Further, because of a
document compiling work being dome by hand, it takes
much time and labor and an error in entry is prone to
come about. Therefore, it has been decided to build up a
system capable of comparing the measured value of the
base position with the design value during measurement
with the reading of the base design value and preparing
of document automated.
3. Built-up System
3.1 System Configuration
Figure 3 shows the system configuration. The system
substantially comprises; personal computer, and printer
installed in the office and further, total station and
controller used at the site. Consideration has been given
so as to enable reading the design value and outputting
the data of document through the personal computer in
the office, but not increasing the machines and materials
used in the field work.
For transmitting the design value and measurement data
between the personal computer in the office and the total
station at the site, the controller of total station is used
and the data are sent and received through a serial
interface.
3.2 Automatic Reading of Design Value
The types of figures drawn in the plan are classified into
a square, straight line and letters and among them, the
straight line has such an attribute as a solid line or a
dimensional line. In the plan, the base plate is drawn by
a square and the design value, as a letter. A figure
linking both is a dimensional line. It has been thought
that by making full use of the linking relation of this figure,
the design value can be read by extraction the base
plate. Figure 4 shows an extraction flow of the base plate.
First, in order to extract the base plate, the squares are
taken out of the plan, from which the following are
excluded : a square adjoining to 4 corners of the plan
( column of entry of DWG. No. and designation of
Computer
Design
Controller
Value
E
CAD Document Med
Date Data ata
Printer
m
Total
Station
Figure 3 System Configuration
249