Full text: Fortschritte in der Metallographie

170 Prakt. Met. Sonderband 47 (2015) 
NiTi vor Schädigung durch den Ionenstrahl zu Schiitzen und fiir detallierte Charakterisierung der 
Topographie und Struktur mittels TEM zu erhalten. 
Literatur 
[1] Kato NI. Reducing focused ion beam damage to transmission electron microscopy samples. 
J Electron Microsc 2004;53:451-8. 
[2] Engelmann HJ. Advantages and disadvantages of TEM sample preparation using the FIB 
technique. Prakt Metallogr-Pr M 2003;40:163-74. 
[3] Langford RM, Huang YZ, Lozano-Perez S, Titchmarsh JM. Preparation of site specific 
transmission electron microscopy plan-view specimens using a focused ion beam system. J 
Vac Sci Technol B 2001;19:755-8. = 
[4] Langford RM, Petford-Long AK. Preparation of transmission electron microscopy CroSS- 
section specimens using focused ion beam milling. J Vac Sci Technol A 2001;19:2186-93. 
[5] Spolenak R, Heiland B, Witt C, Keller RM, Mullner P, Arzt E. The preparation of TEM- 
specimens using Focused Ion Beam (FIB) systems. Prakt Metallogr-Pr M 2000;37:90-101. po 
[6] Rubanov S, Munroe PR. The effect of the gold sputter-coated films in minimising damage in 
FIB-produced TEM specimens. Mater Lett 2003;57:2238-41. 
[7] Dai JY, Tee SF, Tay CL, Song ZG, Ansari S, Er E, et al. Development of a rapid and 
automated TEM sample preparation method in semiconductor failure analysis and the study 
of the relevant TEM artifact. Microelectr J 2001;32:221-6. 
[8] Wang ZG, Kato T, Hirayama T, Kato N, Sasaki K, Saka H. Surface damage induced by 
focused-ion-beam milling. in a Si/Si p-n junction cross-sectional specimen. Applied Surface 
Science 2005;241:80-6. 
[91 Potapov PL, Tirry W, Schryvers D, Sivel VGM, Wu MY, Aslanidis D, et al. Cross-section 
transmission electron microscopy characterization of the near-surface structure of medical 
Nitinol superelastic tubing. J Mater Sci-Mater M 2007;18:483-92. 
[10] Undisz A, Hanke R, Freiberg KE, Hoffmann V, Rettenmayr M. The effect of heating rate on 
the surface chemistry of NiTi. Acta Biomater 2014;10:4919-23. 
[11] Chan CM, Trigwell S, Duerig T. Oxidation of an Niti Alloy. Surf Interface Anal 
1990;15:349-54. 
[12] Firstov GS, Vitchev RG, Kumar H, Blanpain B, Van Humbeeck J. Surface oxidation of NiTi 
shape memory alloy. Biomaterials 2002;23:4863-71. 
[13] Undisz A, Schrempel F, Wesch W, Rettenmayr M. In situ observation of surface oxide 
layers on medical grade Ni-Ti alloy during straining. J Biomed Mater Res A : 
2009;88A:1000-9. Cy
	        
Waiting...

Note to user

Dear user,

In response to current developments in the web technology used by the Goobi viewer, the software no longer supports your browser.

Please use one of the following browsers to display this page correctly.

Thank you.