363
representative sample point, to illustrate where the peak correlations are occurring. This sensitivity to
processing emphasises that the exact wavelength of peak correlation may be misleading - it is possible that
this will different for different data sets. This will have serious implications for the use of standard indices
based on reflectance or derivative at fixed wavelength positions. The absence of such sensitivity in the
visible/NIR region may be due to the higher spectral resolution of the raw data in this wavelength region
or the fact that absorption feature here is an isolated trough compared with the broader feature around
1142nm.
The strength of the relationship between wet% and the Relative Depth Index (as calculated by
Method 2) was found to be relatively insensitive to the degree of spectral smoothing.
Figure 5. Variation in Product Moment Correlation Coefficient between first derivative of
reflectance and canopy wet% for different degrees of data smoothing.
Wavelength (nm)
Figure 6. Réflectance and first derivative across the 1150nm water absorption région.